Dynamic<RangePcl>¶
RepCap Settings
# Range: Nr1 .. Nr5
rc = driver.configure.multiEval.limit.epsk.powerVsTime.lower.upart.dynamic.repcap_rangePcl_get()
driver.configure.multiEval.limit.epsk.powerVsTime.lower.upart.dynamic.repcap_rangePcl_set(repcap.RangePcl.Nr1)
SCPI Commands
CONFigure:GSM:MEASurement<Instance>:MEValuation:LIMit:EPSK:PVTime:LOWer:UPARt<UsefulPart>:DYNamic<RangePcl>
- class Dynamic[source]
Dynamic commands group definition. 1 total commands, 0 Sub-groups, 1 group commands Repeated Capability: RangePcl, default value after init: RangePcl.Nr1
- class DynamicStruct[source]
Structure for setting input parameters. Fields:
Enable: bool: OFF | ON Disable or enable dynamic correction
Pcl_Start: float: numeric First PCL in PCL range Range: 0 to 31
Pcl_End: float: numeric Last PCL in PCL range (can be equal to PCLStart) Range: 0 to 31
Correction: float: numeric Correction value for power template Range: -100 dB to 100 dB, Unit: dB
- get(usefulPart=<UsefulPart.Default: -1>, rangePcl=<RangePcl.Default: -1>) → DynamicStruct[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIMit:EPSK:PVTime:LOWer:UPARt<nr>:DYNamic<Range> value: DynamicStruct = driver.configure.multiEval.limit.epsk.powerVsTime.lower.upart.dynamic.get(usefulPart = repcap.UsefulPart.Default, rangePcl = repcap.RangePcl.Default)
These commands define and activate dynamic (PCL-dependent) corrections to the lower limit lines for the measured power vs. time. The corrections apply to the modulation schemes GMSK, 8PSK (EPSK) or 16-QAM (QAM16) . Each limit line section can consist of different areas (<no>) . Each dynamic correction is defined for up to five different PCL ranges (<Range>) ). In the default configuration, the dynamic corrections for all lower limit lines are set to zero and disabled.
- param usefulPart
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Upart’)
- param rangePcl
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Dynamic’)
- return
structure: for return value, see the help for DynamicStruct structure arguments.
- set(structure: RsCmwGsmMeas.Implementations.Configure_.MultiEval_.Limit_.Epsk_.PowerVsTime_.Lower_.Upart_.Dynamic.Dynamic.DynamicStruct, usefulPart=<UsefulPart.Default: -1>, rangePcl=<RangePcl.Default: -1>) → None[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIMit:EPSK:PVTime:LOWer:UPARt<nr>:DYNamic<Range> driver.configure.multiEval.limit.epsk.powerVsTime.lower.upart.dynamic.set(value = [PROPERTY_STRUCT_NAME](), usefulPart = repcap.UsefulPart.Default, rangePcl = repcap.RangePcl.Default)
These commands define and activate dynamic (PCL-dependent) corrections to the lower limit lines for the measured power vs. time. The corrections apply to the modulation schemes GMSK, 8PSK (EPSK) or 16-QAM (QAM16) . Each limit line section can consist of different areas (<no>) . Each dynamic correction is defined for up to five different PCL ranges (<Range>) ). In the default configuration, the dynamic corrections for all lower limit lines are set to zero and disabled.
- param structure
for set value, see the help for DynamicStruct structure arguments.
- param usefulPart
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Upart’)
- param rangePcl
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Dynamic’)
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.multiEval.limit.epsk.powerVsTime.lower.upart.dynamic.clone()