Dynamic<RangePcl>¶
RepCap Settings
# Range: Nr1 .. Nr5
rc = driver.configure.multiEval.limit.qam.powerVsTime.upper.fallingEdge.dynamic.repcap_rangePcl_get()
driver.configure.multiEval.limit.qam.powerVsTime.upper.fallingEdge.dynamic.repcap_rangePcl_set(repcap.RangePcl.Nr1)
SCPI Commands
CONFigure:GSM:MEASurement<Instance>:MEValuation:LIMit:QAM<QamOrder>:PVTime:UPPer:FEDGe<FallingEdge>:DYNamic<RangePcl>
- class Dynamic[source]
Dynamic commands group definition. 1 total commands, 0 Sub-groups, 1 group commands Repeated Capability: RangePcl, default value after init: RangePcl.Nr1
- class DynamicStruct[source]
Structure for setting input parameters. Fields:
Enable: bool: OFF | ON Disable or enable dynamic correction
Pcl_Start: float: numeric First PCL in PCL range Range: 0 to 31
Pcl_End: float: numeric Last PCL in PCL range (can be equal to PCLStart) Range: 0 to 31
Correction: float: numeric Correction value for power template Range: -100 dB to 100 dB, Unit: dB
- get(qamOrder=<QamOrder.Default: -1>, fallingEdge=<FallingEdge.Default: -1>, rangePcl=<RangePcl.Default: -1>) → DynamicStruct[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIMit:QAM<ModOrder>:PVTime:UPPer:FEDGe<nr>:DYNamic<Range> value: DynamicStruct = driver.configure.multiEval.limit.qam.powerVsTime.upper.fallingEdge.dynamic.get(qamOrder = repcap.QamOrder.Default, fallingEdge = repcap.FallingEdge.Default, rangePcl = repcap.RangePcl.Default)
These commands define and activate dynamic (PCL-dependent) corrections to the upper limit lines for the measured power vs. time. The corrections apply to the modulation schemes GMSK, 8PSK (EPSK) or 16-QAM (QAM16) and to the three limit line sections: rising edge (REDGe) , useful part (UPARt) and falling edge (FEDGe) . Each limit line section consists of several areas (<no>) . Each dynamic correction is defined for up to five different PCL ranges (<Range>) ).
- param qamOrder
optional repeated capability selector. Default value: Nr16 (settable in the interface ‘Qam’)
- param fallingEdge
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘FallingEdge’)
- param rangePcl
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Dynamic’)
- return
structure: for return value, see the help for DynamicStruct structure arguments.
- set(structure: RsCmwGsmMeas.Implementations.Configure_.MultiEval_.Limit_.Qam_.PowerVsTime_.Upper_.FallingEdge_.Dynamic.Dynamic.DynamicStruct, qamOrder=<QamOrder.Default: -1>, fallingEdge=<FallingEdge.Default: -1>, rangePcl=<RangePcl.Default: -1>) → None[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIMit:QAM<ModOrder>:PVTime:UPPer:FEDGe<nr>:DYNamic<Range> driver.configure.multiEval.limit.qam.powerVsTime.upper.fallingEdge.dynamic.set(value = [PROPERTY_STRUCT_NAME](), qamOrder = repcap.QamOrder.Default, fallingEdge = repcap.FallingEdge.Default, rangePcl = repcap.RangePcl.Default)
These commands define and activate dynamic (PCL-dependent) corrections to the upper limit lines for the measured power vs. time. The corrections apply to the modulation schemes GMSK, 8PSK (EPSK) or 16-QAM (QAM16) and to the three limit line sections: rising edge (REDGe) , useful part (UPARt) and falling edge (FEDGe) . Each limit line section consists of several areas (<no>) . Each dynamic correction is defined for up to five different PCL ranges (<Range>) ).
- param structure
for set value, see the help for DynamicStruct structure arguments.
- param qamOrder
optional repeated capability selector. Default value: Nr16 (settable in the interface ‘Qam’)
- param fallingEdge
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘FallingEdge’)
- param rangePcl
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Dynamic’)
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.multiEval.limit.qam.powerVsTime.upper.fallingEdge.dynamic.clone()