Sswitching¶
SCPI Commands
FETCh:GSM:MEASurement<Instance>:MEValuation:SSWitching
READ:GSM:MEASurement<Instance>:MEValuation:SSWitching
- class Sswitching[source]
Sswitching commands group definition. 7 total commands, 1 Sub-groups, 2 group commands
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal ‘Reliability Indicator’
Out_Of_Tol_Count: float: float Percentage of measurement intervals / bursts of the statistic count ([CMDLINK: CONFigure:GSM:MEASi:MEValuation:SCOunt:SSWitching CMDLINK]) exceeding the specified limits, see ‘Limits (Spectrum Switching) ‘ Range: 0 % to 100 %, Unit: %
Carrier_Power: float: float Measured carrier output power (reference power) Range: -100 dBm to 55 dBm, Unit: dBm
- fetch() → ResultData[source]
# SCPI: FETCh:GSM:MEASurement<Instance>:MEValuation:SSWitching value: ResultData = driver.multiEval.sswitching.fetch()
Returns general spectrum switching results.
- return
structure: for return value, see the help for ResultData structure arguments.
- read() → ResultData[source]
# SCPI: READ:GSM:MEASurement<Instance>:MEValuation:SSWitching value: ResultData = driver.multiEval.sswitching.read()
Returns general spectrum switching results.
- return
structure: for return value, see the help for ResultData structure arguments.
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.multiEval.sswitching.clone()
Subgroups