CONFigure:GSM:MEASurement<Instance>:MEValuation:LIST:SEGMent<Segment>:BER
- class Ber[source]
Ber commands group definition. 1 total commands, 0 Sub-groups, 1 group commands
- class BerStruct[source]
Structure for setting input parameters. Contains optional setting parameters. Fields:
Statistic: int: integer The statistical length is defined in slots. It is limited by the number of evaluated slots (defined via step length or frame pattern) . Range: 1 to 100
Enable: bool: OFF | ON ON: Enable BER measurement OFF: Disable measurement
Loop_Type: enums.LoopType: C | SRB C: Loop C SRB: SRB loop
Frame_Pattern: str: Optional setting parameter. binary 8-digit binary value, defines the evaluated timeslots in each TDMA frame. Used only if no step length is configured (see [CMDLINK: CONFigure:GSM:MEASi:MEValuation:LIST:SLENgth CMDLINK]) . Range: #B00000000 to #B11111111 (no slots … all slots measured)
- get(segment=<Segment.Default: -1>) → BerStruct[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:BER value: BerStruct = driver.configure.multiEval.listPy.segment.ber.get(segment = repcap.Segment.Default)
Defines the statistical length for averaging and enables the BER measurement in segment no. <no>; see ‘List Mode’.
- param segment
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)
- return
structure: for return value, see the help for BerStruct structure arguments.
- set(structure: RsCmwGsmMeas.Implementations.Configure_.MultiEval_.ListPy_.Segment_.Ber.Ber.BerStruct, segment=<Segment.Default: -1>) → None[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:BER driver.configure.multiEval.listPy.segment.ber.set(value = [PROPERTY_STRUCT_NAME](), segment = repcap.Segment.Default)
Defines the statistical length for averaging and enables the BER measurement in segment no. <no>; see ‘List Mode’.
- param structure
for set value, see the help for BerStruct structure arguments.
- param segment
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)