Sswitching

SCPI Commands

CONFigure:GSM:MEASurement<Instance>:MEValuation:LIST:SEGMent<Segment>:SSWitching
class Sswitching[source]

Sswitching commands group definition. 1 total commands, 0 Sub-groups, 1 group commands

class SswitchingStruct[source]

Structure for setting input parameters. Contains optional setting parameters. Fields:

  • Statistic: int: integer The statistical length is defined in slots. It is limited by the number of evaluated slots (defined via step length or frame pattern) . Range: 1 to 100

  • Enable: bool: OFF | ON ON: Enable measurement of spectrum due to switching (including the ‘spectrum switching time’ results in offline mode) OFF: Disable measurement

  • Frame_Pattern: str: Optional setting parameter. binary 8-digit binary value, defines the evaluated timeslots in each TDMA frame. Used only if no step length is configured (see [CMDLINK: CONFigure:GSM:MEASi:MEValuation:LIST:SLENgth CMDLINK]) . Range: #B00000000 to #B11111111 (no slots … all slots measured)

get(segment=<Segment.Default: -1>)SswitchingStruct[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:SSWitching
value: SswitchingStruct = driver.configure.multiEval.listPy.segment.sswitching.get(segment = repcap.Segment.Default)

Defines the statistical length for the maximum calculation (peak hold mode) and enables the spectrum due to switching measurement in segment no. <no>; see ‘List Mode’.

param segment

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Segment’)

return

structure: for return value, see the help for SswitchingStruct structure arguments.

set(structure: RsCmwGsmMeas.Implementations.Configure_.MultiEval_.ListPy_.Segment_.Sswitching.Sswitching.SswitchingStruct, segment=<Segment.Default: -1>)None[source]
# SCPI: CONFigure:GSM:MEASurement<Instance>:MEValuation:LIST:SEGMent<nr>:SSWitching
driver.configure.multiEval.listPy.segment.sswitching.set(value = [PROPERTY_STRUCT_NAME](), segment = repcap.Segment.Default)

Defines the statistical length for the maximum calculation (peak hold mode) and enables the spectrum due to switching measurement in segment no. <no>; see ‘List Mode’.

param structure

for set value, see the help for SswitchingStruct structure arguments.

param segment