Average

SCPI Commands

FETCh:GSM:MEASurement<Instance>:MEValuation:LIST:MODulation:APDelay:AVERage
CALCulate:GSM:MEASurement<Instance>:MEValuation:LIST:MODulation:APDelay:AVERage
class Average[source]

Average commands group definition. 2 total commands, 0 Sub-groups, 2 group commands

calculate()List[float][source]
# SCPI: CALCulate:GSM:MEASurement<Instance>:MEValuation:LIST:MODulation:APDelay:AVERage
value: List[float] = driver.multiEval.listPy.modulation.apDelay.average.calculate()

Return AM-PM delay results for all measured list mode segments. The values described below are returned by FETCh commands. CALCulate commands return limit check results instead, one value for each result listed below.

Use RsCmwGsmMeas.reliability.last_value to read the updated reliability indicator.

return

am_pm_delay: float Comma-separated list of values, one per measured segment Range: -0.9225E-6 s to 0.9225E-6 s, Unit: s

fetch()List[float][source]
# SCPI: FETCh:GSM:MEASurement<Instance>:MEValuation:LIST:MODulation:APDelay:AVERage
value: List[float] = driver.multiEval.listPy.modulation.apDelay.average.fetch()

Return AM-PM delay results for all measured list mode segments. The values described below are returned by FETCh commands. CALCulate commands return limit check results instead, one value for each result listed below.

Use RsCmwGsmMeas.reliability.last_value to read the updated reliability indicator.

return

am_pm_delay: float Comma-separated list of values, one per measured segment Range: -0.9225E-6 s to 0.9225E-6 s, Unit: s